{"id":1672,"date":"2024-10-25T11:19:40","date_gmt":"2024-10-25T11:19:40","guid":{"rendered":"https:\/\/concordevalves.com\/blogs\/?p=1672"},"modified":"2024-12-21T09:19:43","modified_gmt":"2024-12-21T09:19:43","slug":"what-is-a-wafer-check-valve","status":"publish","type":"post","link":"https:\/\/concordevalves.com\/blogs\/what-is-a-wafer-check-valve\/","title":{"rendered":"What is a Wafer Check Valve?"},"content":{"rendered":"<h1><strong>Wafer Check Valve: The Complete Guide for Industrial Use<\/strong><\/h1>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"2\">The compactness of wafer check valves makes them an essential component in many industrial applications. They prevent backflow in pipelines and save space.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"3\">Wafer check valves have a high value in industries like oil and gas processing, water treatment and chemical production because of their robustness, low maintenance and efficiency.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"4\">The article will cover all the information you need about wafer-check valves including types, requirements for installation, sizes, and uses.<\/span><\/p>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"5\">What is a Wafer Check Valve?<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"6\">A <a href=\"https:\/\/concordevalves.com\/blogs\/what-is-a-wafer-check-valve\/\"><strong>Wafer Check Valve<\/strong><\/a>\u00a0prevents the flow of fluids backwards through a pipe.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"7\">Wafer check valves fit easily between two flanges and are lighter than conventional check valves.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"8\">The streamlined design reduces the footprint of the valve, which makes it perfect for areas with restricted installation space.<\/span><\/p>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"9\">The wafer check valves are operated by a disc that opens automatically with the forward flow, and shuts off when the reverse flow occurs. This prevents backflow effectively without external activation.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"10\">They are popular in many industries because of their efficiency and simplicity.<\/span><\/p>\n<h2><strong>Types of Wafer Check Valves<\/strong><\/h2>\n<h3><strong>Wafer Type Check Valve<\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"13\">The wafer type check valve\u00a0has become one of the more common types in industry.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"14\">The thin design allows it to fit between the flanges of a pipeline, which reduces the need for extensive pipe modifications.<\/span> Check valve wafer types<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"15\">\u00a0is known for its simplicity and reliability. It&#8217;s ideal for applications that require quick installation.<\/span><\/p>\n<h3><strong>Wafer Swing Check Valve<\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"17\">The wafer swing check valve\u00a0uses a disc hinged to swing open and allow fluid to flow one way, then swing backwards to block reverse flow.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"18\">The design of this valve is especially useful for applications that require low pressure drops and minimum resistance to fluid flow.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"19\">Due to their high efficiency, wafer swinging check valves are used in industries such as HVAC, process engineering, water distribution and more.<\/span><\/p>\n<h3><strong>Dual Plate Check Valve Wafer Type<\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"21\">The dual plate check valve wafer type\u00a0has two discs or plates that open when there is forward flow, and then close once the flow reverses or stops.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"22\">The durability of this type and its ability to handle high pressures make it ideal for oil, gas, and chemical applications where backflow prevention is critical.<\/span><\/p>\n<h3><strong>Single Plate Wafer Check Valve<\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"24\">A single plate wafer check valve\u00a0controls the flow with a single disk, offering an easy-to-use mechanism that requires minimal components.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"25\">The simple design minimizes maintenance needs and is suitable for various low-to-medium-pressure applications, including water systems and irrigation.<\/span><\/p>\n<h3><strong>Wafer Disc Check Valve<\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"27\">Wafer disc check valves control the flow of fluid by using a disc which moves axially inside the valve housing.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"28\">A spring holds the disc in place, which allows it to respond quickly to changes in pressure.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"29\">The disc is a good choice for applications that involve fluids moving quickly, because its quick response allows it to maintain a stable flow.<\/span><\/p>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"30\">Wafer check valves: Benefits and Use<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"31\">In industrial applications, wafer check valves have many advantages, such as their small size, affordability, and high performance.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"32\">Take a look at some of their advantages:<\/span><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"33\"><strong>Space Saving Design:<\/strong>\u00a0Wafer Check Valves are lightweight and compact, making it easy to place them between flanges. This reduces the footprint of the valve and makes them ideal for tight spaces.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"34\"><strong>Low-Maintenance:<\/strong>\u00a0Due to the simple design of wafer check vales, they require less maintenance than other types.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"35\"><strong>Efficient backflow prevention:<\/strong>\u00a0These valves protect pumps and sensitive equipment against potential damage.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"36\"><strong>Wide range of applications<\/strong>: Wafer check valves are available in a variety of types, including swing, dual-plate, and single-plate.<\/span><\/li>\n<\/ul>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"37\">Application of Wafer Check Valves<\/span><\/strong><\/h2>\n<h3><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"38\">Oil and Gas Industry<\/span><\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"39\">Wafer check valves can be used in the oil and gasoline industry to stop backflow from pipelines, storage tanks, and pumps.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"40\">The <strong><a href=\"https:\/\/kitzvalvesdistributors.blogspot.com\/2022\/02\/wafer-check-valve.html\" target=\"_blank\" rel=\"noopener\">dual plate wafer checks<\/a><\/strong> are popular due to their reliability and strength in high pressure environments. They ensure safe operations in drilling and refinery applications.<\/span><\/p>\n<h3><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"41\">Water Treatment Facilities<\/span><\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"42\">In water treatment plants, wafer check valves control fluid flow in filtration systems and pipes.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"43\">Compact design of the wafer check valve helps to streamline water systems, and reduces contamination risk from backflow.<\/span><\/p>\n<h3><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"44\">Chemical Processing<\/span><\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"45\">Wafer check valves are used in chemical processing plants to control corrosive and high temperature fluids.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"46\">Single plate wafer checks are often chosen because of their durability and compatibility in chemical environments.<\/span><\/p>\n<h3><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"47\">HVAC System<\/span><\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"48\">wafer type swing check valves regulate the air and water flows in HVAC systems. They prevent backflow, which could cause damage to the system, or decrease its efficiency.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"49\">The space-saving features of wafer check valves make them perfect for HVAC systems where there is a limited amount of space.<\/span><\/p>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"50\">Installing a Wafer-Check Valve<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"51\">Wafer check valve installation can be simple, but it requires that you pay attention to the details to get the best performance.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"52\">Here are general installation steps:<\/span><\/p>\n<ol>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"53\"><strong>Preparing the Piping System:<\/strong>\u00a0Ensure that the pipe is clear of debris. Particles can block the valve.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"54\">Verify that the flanges have been aligned properly.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"55\"><strong>Place the Valve Correctly<\/strong>: Position the wafer-check valve between the flanges.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"56\">Make sure that the flow direction arrow aligns with where the fluid is flowing in the pipe.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"57\"><strong>Evenly tighten Flanges<\/strong>: To secure the valve, evenly tighten all bolts on the flanges.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"58\">Overtightening can cause damage to the valve.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"59\"><strong>Check for Correct Operation:<\/strong>\u00a0After installing the valve, check to make sure it is working correctly.<\/span><\/li>\n<\/ol>\n<h3><strong>Wafer Check Valve Dimensions PDF and Sizing Guide<\/strong><\/h3>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"61\">The right size for wafer check valve installation\u00a0is essential.<\/span> wafer check valve dimensions PDF<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"62\">\u00a0is often supplied by manufacturers such as Concorde Valves. It provides detailed information on sizing to assist you in choosing the right fit for your pipeline needs.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"63\">The correct size is essential for proper function and to reduce the possibility of any operational problems.<\/span><\/p>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"64\">Materials Options for Wafer-Check Valves<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"65\"><strong>Check valves<\/strong>\u00a0are available in a variety of materials and each is suitable for varying applications.<\/span><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"66\"><strong>Stainless Steel<\/strong>\u00a0: Resistant against corrosion making it suitable for water and chemical applications.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"67\"><strong>Cast iron (CI Wafer-Type Check Valve):<\/strong>\u00a0is often used for lower pressure environments because of its cost-effectiveness and durability.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"68\"><strong>Composites of PVC and plastic:<\/strong>\u00a0are lightweight and corrosion resistant, and suitable for applications like irrigation.<\/span><\/li>\n<\/ul>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"69\">Comparison of Single and Dual-Plate Wafer Check Valves<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"70\">Both single-plate and dual-plate wafer check valves prevent backflow but they perform differently.<\/span><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"71\"><strong>Single Plate Wafer Check Valve:<\/strong>\u00a0Has one disc, and it is designed for medium pressure.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"72\">It is easier to maintain and ideal for standard applications.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"73\"><strong>Dual Plate Wafer Check Valve:<\/strong>\u00a0has two plates to increase stability. It can also handle greater pressures.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"74\">Used in industrial settings that are demanding.<\/span><\/li>\n<\/ul>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"75\">Understanding the operation of a Wafer type Swing check Valve<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"76\">The wafer type swing check valve\u00a0works by swinging the disc away from its seat in order to allow forward flow.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"77\">The disc returns to its original position when the flow is reversed, sealing the valve.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"78\">The type of valve is perfect for applications with low pressure, as it provides a simple but effective mechanism to prevent backflow.<\/span><\/p>\n<h2><strong>Key Differences: Wafer Check Valve vs. Traditional Check Valve<\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"81\">The advantages of wafer check valves over conventional check valves are numerous.<\/span><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"82\"><strong>Compact design: <\/strong>Wafer Check Valves are lighter and smaller, taking up less space.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"83\"><strong>Installation Made Easy<\/strong>: These can be easily installed between flanges, without requiring extensive modification.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"84\"><strong>Lower pressure drop<\/strong>: Streamlined design for efficiency and minimal resistance.<\/span><\/li>\n<\/ul>\n<h2><strong>Wafer Check Valve Maintenance Tips<\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"86\">Maintenance is essential to ensure a long-lasting product and consistent performance.<\/span><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"87\"><strong>Check the discs for wear and tear<\/strong>: Inspect all components, including the discs and their parts regularly.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"88\"><strong>Clean Operation:<\/strong>\u00a0Remove debris around valves to ensure smooth operation.<\/span><\/li>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"89\"><strong>Replacing Damaged Parts Quickly<\/strong>\u00a0: Replace damaged parts immediately if you see any signs of damage.<\/span><\/li>\n<\/ul>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"90\">Catalog of Wafer-Type Check Valves and Customization Options<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"91\"><strong><a href=\"https:\/\/concordevalves.com\/\">Concorde Valves and Automations<\/a><\/strong> manufacturers offer a variety of choices for their wafer type check valve catalog.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"92\">The customizations can include the material, size and pressure rating.<\/span><\/p>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"93\">Images of Wafer-Check Valves for Visual Reference<\/span><\/strong><\/h2>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"94\">The images of wafer check valves\u00a0illustrate the compact designs and different configurations.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"95\">Companies like Concorde Valves &amp; Automations offer visual guides in their product catalogs or PDFs to help you understand the structure of the valve.<\/span><\/p>\n<h2><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"96\">FAQ<\/span><\/strong><\/h2>\n<p><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"97\">What&#8217;s the difference between wafer and swing check valves?<\/span><\/strong><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"98\">Wafer check valves are compact, and fit between flanges. Swing check valves have a large design, and connect directly to the pipe.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"99\">For tight spaces, wafer check valves should be used.<\/span><\/li>\n<\/ul>\n<p><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"100\">What is the best wafer-check valve to use for my application and how do I choose it?<\/span><\/strong><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"101\">You should consider factors like fluid type, required pressure, and the size of your valve.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"102\">The wafer check valve catalog\u00a0will help you choose the right model.<\/span><\/li>\n<\/ul>\n<p><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"103\">Can wafer check vales be used in high-pressure applications?<\/span><\/strong><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"104\">Dual plate valves are designed to handle high pressures.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"105\">For lower pressures, single plate check valves and swinging check valves may be used.<\/span><\/li>\n<\/ul>\n<p><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"106\">What is the recommended maintenance schedule for a wafer-check valve?<\/span><\/strong><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"107\">For optimal performance, it is best to inspect the valves every 6-12months.<\/span><\/li>\n<\/ul>\n<p><strong><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"108\">Which materials are used most commonly for wafer-check valves?<\/span><\/strong><\/p>\n<ul>\n<li><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"109\">Cast iron (CI), PVC, and stainless steel are all common.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"110\">Cast iron (CI) is an economical option for standard applications and is suitable for harsh conditions. Stainless steel, on the other hand, is resistant to corrosion.<\/span><\/li>\n<\/ul>\n<p><span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"112\">With their reliable performance and compact design, wafer check valves play an important role in industrial flow systems.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"113\">They are popular in many industries from oil and gas to water treatment because of their versatility and easy installation.<\/span>\u00a0<span class=\"wordai-block rewrite-block enable-highlight\" data-id=\"114\">Understanding the different types of wafer check vales, their applications and how to install them will help you make an informed choice for your application. This ensures optimal performance and durability.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Wafer Check Valve: The Complete Guide for Industrial Use The compactness of wafer check valves makes them an essential component [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1779,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[9],"class_list":["post-1672","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-wafer-check-valve"],"uagb_featured_image_src":{"full":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve.webp",1200,628,false],"thumbnail":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve-150x150.webp",150,150,true],"medium":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve-300x157.webp",300,157,true],"medium_large":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve-768x402.webp",768,402,true],"large":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve-1024x536.webp",1024,536,true],"1536x1536":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve.webp",1200,628,false],"2048x2048":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve.webp",1200,628,false],"web-stories-poster-portrait":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve-640x628.webp",640,628,true],"web-stories-publisher-logo":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve-96x96.webp",96,96,true],"web-stories-thumbnail":["https:\/\/concordevalves.com\/blogs\/wp-content\/uploads\/2024\/10\/wafer-check-valve-150x79.webp",150,79,true]},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/concordevalves.com\/blogs\/author\/concordevalves\/"},"uagb_comment_info":0,"uagb_excerpt":"Wafer Check Valve: The Complete Guide for Industrial Use The compactness of wafer check valves makes them an essential component [&hellip;]","_links":{"self":[{"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/posts\/1672","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/comments?post=1672"}],"version-history":[{"count":4,"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/posts\/1672\/revisions"}],"predecessor-version":[{"id":1677,"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/posts\/1672\/revisions\/1677"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/media\/1779"}],"wp:attachment":[{"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/media?parent=1672"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/categories?post=1672"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/concordevalves.com\/blogs\/wp-json\/wp\/v2\/tags?post=1672"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}